Dual evap refrigeration

For example, many dual evaporator systems have separate refrigeration cycles for the freezer compartment and the fresh food compartment.

Whirlpool dual evaporator refrigerator

This allows fresh produce and unsealed foods to stay fresh longer. Moisture sensitive foods can be stored on open shelves without a lot of moisture loss. Now all thats nice and good unless you visit the USDA website and look at their recommendations for food storage. If the compressor is not running, the condenser fan can be the problem. On the board there will be a plug marked J Therefore, the main board can cause both the fresh food section and the freezer section to stop cooling. On the board you should see a connector marked J2, this is the fan motor plug. Dual evaporator refrigeration systems have certain advantages over single evaporator refrigeration systems. Ya the food may have a nice color, be chrispy or whatever attitributes it should have, but guess what's missing, according to USDA?? The phase separator is coupled to an input of the first evaporator and an input of the second evaporator, wherein the phase separator provides a refrigerant stream in a vapor phase part and a liquid phase part to the input of the first evaporator and a refrigerant stream in a liquid phase to the input of the second evaporator. Particularly fruits and veggies. Test for voltage by probing pin 3 third pin from left with your black lead and your red lead on pin 8. If the fan is running but the compressor is not, then the main board is more than likely the problem. Using an ohmmeter test for continuity from each of the three terminals on the compressor.

Refrigerant flow control techniques are provided whereby a compressor in the refrigerator appliance that receives a resulting refrigerant stream is required to do less work to raise the pressure of the stream, and thus the refrigerator appliance is more energy efficient.

The phase separator is coupled to an input of the first evaporator and an input of the second evaporator, wherein the phase separator provides a refrigerant stream in a vapor phase part and a liquid phase part to the input of the first evaporator and a refrigerant stream in a liquid phase to the input of the second evaporator.

dual evaporator refrigerator problems

Another good advantage is that the humidity of the fresh food section is significantly higher. Look to the right of the compressor and you should see a fan, if the compressor is running or supposed to be runningthe fan should be running.

Kitchenaid dual evaporator refrigerator problems

Locate the main board on the back of the refrigerator. Dual evaporator refrigeration systems have a separate cooling system for each side of the product, keeping them at different temperatures, but choosing whether to get one of these systems is a measure of needs and budget. Another good advantage is that the humidity of the fresh food section is significantly higher. If this is not what your refrigerator is doing, here are other pages on GE ClimateKeeper refrigerator repair. Disadvantages of the Dual Evaporator The biggest disadvantage is, of course, the cost. But when both the fresh food section and the freezer section are not working you must treat it as one refrigerator. Another aspect of the present invention relates to a dual evaporator refrigerator appliance comprising a first evaporator, a second evaporator and a refrigerant stream combining device. Since some folks with obviously more "esoteric taste buds" than me, have detected differences in food stored in Dual compressor fridges"More power to them" 2 motors take more power than one , or at the very least run more????. The refrigerant stream combining device is coupled to an output of the first evaporator and an output of the second evaporator, wherein the refrigerant stream combining device receives a first refrigerant stream having a first pressure from the output of the first evaporator and a second refrigerant stream having a second pressure from the output of the second evaporator, and generates an output refrigerant stream having a pressure greater than the second pressure.

On the board you should see a connector marked J2, this is the fan motor plug. So at least to methis Dual thing is just "marketing Goobledegoop". Replacing a compressor is not a do-it-yourself repair job. More than likely you are apt to pick up an "Off taste Flavour" from something that has been kept too long in the Fridge, or Freezer.

Counter depth refrigerator with dual evaporators

To check this, locate the board on the back of the refrigerator. Dual evaporator refrigeration systems have certain advantages over single evaporator refrigeration systems. Also if it is a variable speed compressor, there will be an inverter attached to the side of the compressor and if it is a variable speed compressor the main board will have a plug marked J15 with a wire connected to it. Using an ohmmeter test for continuity from each of the three terminals on the compressor. The SZ is actually a separate Fridge and Freezer built into the same cabinet. Some folks, and of course SZ marketing ,claim that this eliminates the "Odor-transference issue", but being here on Terra Firma, for almost 70 years now, and even with my grandmother's old Sorval SP" gas fridge, I have yet to taste "Odor transferrence". One or both of them should be frosty if the compressor is running. Disconnect power to the refrigerator and remove the inverter. A typical post, "This new fridge keeps food longer than any fridge I've ever had". The best way to check this type of problem is to check the fan supply voltage. The refrigerant stream combining device is coupled to an output of the first evaporator and an output of the second evaporator, wherein the refrigerant stream combining device receives a first refrigerant stream having a first pressure from the output of the first evaporator and a second refrigerant stream having a second pressure from the output of the second evaporator, and generates an output refrigerant stream having a pressure greater than the second pressure.

The SZ is actually a separate Fridge and Freezer built into the same cabinet. Thus, the compressor that receives the refrigerant exiting the freezer evaporator must do more work to raise the refrigerant pressure before sending it to the condenser, as compared with the higher pressure refrigerant exiting the fresh food evaporator.

dual refrigerator
Rated 7/10 based on 80 review
Download
Dual Compressors? Dual Evaporators? Someone pls explain these